HOME ABOUT US CALIBRATION CONTACT US
PRESCIENCE CALIBRATION PVT LTD.

Prescience Calibration

ISO 17025 Accredited

By offering calibration service for DC Nutrunner, torque transducers, angle encoder, transducer power tools, and rotating torque tools, optical level, theodolite, total station, point laser, line laser, rotation laser, Prescience Calibration has earned a unique position by complying to NABL Standards for getting accredited for calibration of DC Nutrunner for the first time in India among calibration laboratories. The laboratory is in all compliance to ISO IEC 17025 (NABL Accreditation), the calibration laboratory quality standard. This implies a high level of technical competence and well documented, traceable calibrations. It is thus assured that the calibration services offered are in compliance with ISO 9000 and ISO/TS 16949 and any other standard as applicable. Laboratory backed up by Technical expertise over decade in Calibration of Nutrunner also offers on-site calibration service


BIPM Definition
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or secondary standard) and, in a second step, uses this information to establish a relation for obtaining a measurement result from an indication."

DC Nutrunner Torque and Angle Calibration
Prescience Calibration follows VDI 2645 Standard

DC Nutrunner 
      Calibration

DC Nutrunner Calibration

Transducerized tools (DC Nutrunner or any torque tool) must be tested regularly in order to establish continued trueness of the delivered torque. Thus, it must be checked that the tool controller reading agrees with the reading of a torque reference transducer. This operation is often called tool calibration. It is based on a certain number of readings, generally at least 25. The average discrepancy between the tool and the reference must lie within tolerance. If not, an adjustment must be made

When a transducerized power tool (DC Nutrunner and other torque tools) is used, it is connected to a controller which runs and monitors the torque tool. The controller is part of a torque and angle measuring system and must be calibrated to maintain accurate torque tool operation. The controller must be calibrated both on a regular basis and following a service, when parts which may influence the torque measurement have been exchanged.

Rotary Torque Tool

All tools are subject to mechanical stress, e.g., gears, bearings and motors are subject to wear. As a result, a tool may not deliver its expected torque or may not be as accurate as expected. The consequences are obvious. Nuts and screws may not be tightened to the prescribed torque, joints may fail and some may even cause injuries. To avoid this, tools need regular calibration

Shut off type torque tools either battery operated torque tool or pneumatic torque tool need calibration at regular intervals.Prescience calibration specializes in calibration of battery operated torque tool and air operated torque tool in accordance with VDI 2645 standard. We provide the tool capability value along with calibration certificate.

Rotary torque tool
Calibration of battery and air operated tool

Rotary torque tool 
      Calibration, battery torque tool
Survey Instruments

Survey Instruments Calibration

ISO 17025 Accredited only laboratory in India

OPTICAL INSTRUMENTS increase alignment accuracy and decrease measurement time—all while providing stable, repeatable reference lines with no deviation. The science of optical metrology and alignment, utilizing optical tools, makes it possible to achieve the highest degree of accuracy when aligning precision systems that are straight, flat, plumb or square. The straight-edge, square and surface tables are the basic tools used by the engineer and each has its counterpart in optical alignment. Direct precision measurements are made rapidly and consistently. It is no longer necessary to extrapolate readings, or to make constant adjustments and calculations

Prescience Calibration has masters for calibration of survey instruments calibrated from NPL, which ensures highest quality of service delivery and traceability to national standard. Prescience Calibration is accredited in India for calibration of optical level, theodolite and total station.
Prescience Calibration undertakes the calibration of following optical Instruments.

  • Optical Level Calibration
  • Theodolite Calibration
  • Total Station Calibration
  • Optical Level Calibration
    Theodolite Calibration
    Total Station Calibration
    Optical Level Calibration

    LASER CALIBRATION

    Laser Level Calibration

    Calibration of Laser Level instruments for first time in India as per International Standard, traceable to National Standards. Prescience Calibration offers calibration service of following Laser Instrumrnts

  • Point Laser Calibration
  • Line Laser Calibration
  • Rotation Laser Calibration
  • Point Laser Calibration
    Line Laser Calibration
    Rotation Laser Calibration